 AC-DC
212 Watts EMA212 Series
* * * * * * * * 3.00" x 5.00" x 1.34"
xppower.com
High Power Density - 10.6 W/in3 Up to 90% Efficiency 5 V Standby & 12 V Fan Outputs Active Current Share Remote On/Off Power Good Signal 48 VDC Input Versions Available (DMA212)
Specification
Input
* 90-264 VAC * 47-63 Hz * 2.2 A max at 115 VAC, 1.1 A max at 230 VAC Inrush Current * 60 A max at 230 VAC, cold start at +25 C Power Factor * >0.9 typical Earth Leakage Current * 1.1 mA max 264 VAC/50 Hz, 500 A typical at 230 VAC/50 Hz, 290 A typical at 115 VAC/60 Hz Input Voltage Input Frequency Input Current
General
Efficiency Isolation * 88% typical * 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VDC Output to Ground * 80 kHz typical for PFC, 100 kHz typical for main converter * 10.6 W/In3 * Combined PF & DC OK - Open collector referenced to output 0 V, transistor normally off when AC & output good. PF provides 5 ms warning of loss of output from AC failure. DC OK provides warning of DC output failure. * 212 kHrs per MIL-HDBK-217F, 25 C GB
Switching Frequency Power Density Signals
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Drift Line Regulation Load Regulation Cross Regulation Over/Undershoot Transient Response * * * * * * * * * * * * * See table No user adjustment available V1: 1%, V2: 5%, V3: 3% No minimum load required <3 s maximum 20 ms maximum 16 ms minimum <0.2% after 20 min warm up V1: 0.5%, V2: 2%, V3: 0.5% V1: 1% 0-100% load, V2: 1% 10-100% load, V3: 1% 0-100% load V2: 10% 10-100% load change on V1 <2% max at turn on/off for 12 V models, <5% for 24 V & 48 V models <4% max deviation for a 25-75-25% load step. Output V1 returns to within 1% in 500 s V1 & V3: 1%, V2: 2% pk-pk, 20 MHz BW 115-140% Vnom, recycle input to reset (output 1 only) Primary & secondary protection with auto recovery 110-140%, auto recovery output 1 Trip and restart (Hiccup mode) 0.05%/C
MTBF
Environmental
Operating Temperature * -10 C to +70 C, derate linearly from +50 C at 2.5%/C to 50% at +70 C Cooling * 12 CFM airflow required (see thermal considerations) Operating Humidity * 5-95% RH, non-condensing Storage Temperature * -20 C to +85 C Operating Altitude * 3000 m Shock * 30 g pk, half sine 6 axes Vibration * 2 g, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Emissions Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals * EN55022, level B conducted EN55022, level A radiated * EN61000-3-2, class A * EN61000-3-3 * EN61000-4-4, level 3 Perf Criteria A * EN61000-4-5, level 3 Perf Criteria A * EN61000-4-6, 10 Vrms, Perf Criteria A * EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B * CB report IEC60950-1:2001, CSA 22.2 No. 60950-1-03, TUV EN60950-1/A11:2004, CE Mark (LVD), CCC pending, contact sales
Ripple & Noise * Overvoltage Protection * Overtemperature Protection Overload Protection Short Circuit Protection Temperature Coefficient Remote On/Off Current Share * * * *
* Uncommitted isolated opto-coupler diode, powered diode inhibits the supply * For increased power, up to 3 supplies to share within 10%, derate total output to 90%
AC-DC
Models and Ratings
Max Output Power (12 CFM Air Flow) 212 W 212 W 205 W Ouput Voltage V1 12.0 VDC 24.0 VDC 48.0 VDC Ouput Current (12 CFM Airflow) 16.7 A 8.3 A 4.0 A Fan Output V2 12.0 V/1.0 A 12.0 V/1.0 A 12.0 V/1.0 A Standby Supply V3 5.0 V/0.1 A 5.0 V/0.1 A 5.0 V/0.1 A
EMA212
Model Number EMA212PS12^ EMA212PS24^ EMA212PS48^
Available from Farnell. See pages 204-206.
^ Available from Newark. See pages 207-208.
Mechanical Details
5.00 (127.0) 0.22 (5.7) 4.55 (115.6)
CN3 6 10 5 1 1 2 2 CN2 1 CN2
TR4
TR11 C14
CN2 +ve
AIR FLOW 12 CFM
(See Thermal considerations)
3.00 2.55 (76.2) (64.8)
SCREW TYPE
-ve
6.35 mm FASTONTYPE(2)
N CN1 L
T7
C42
SAFETY EARTH - 4.8 mm Faston
4 X o 0.14 (3.5) MOUNTING HOLES
1.22 (31.0)
0.06 (1.5)
0.06 (1.5)
Notes 1. All dimensions in inches (mm). 2. Units supplied with screw terminal (CN2) as standard. For faston type, add suffix `-F' to the part number. 3. All 4 mounting positions should be connected to safety earth. 4. The air flow needs to be directed through the power supply within the end application.
PIN CONNECTIONS - CN2 1 2 +V1 V1 Return PIN CONNECTIONS - CN3 1 2 3 4 5 6 7 8 9 10 +V2 V2 Return V2 Return ROF ROF Return Power Fail/DC OK Current Share +V3 -V3 +V2 Mating Connectors: CN1: Molex housing 09-50-3031 and crimp 2878. CN3: Molex housing 51110-1050 and crimp 50394-8100.
Thermal Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. See drawing above for component locations. The temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). See longform datasheet for more information concerning service life.
Temperature Measurements (Ambient 50 C) 110 C 105 C 105 C 110 C 120 C
Component TR4 case C14 C42 TR11 case T7 coil
Max Continuous Temperature C
24-Sept-08


▲Up To Search▲   

 
Price & Availability of EMA212PS12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X